this website uses cookies to ensure you get the best experience on our website.

close
Mode Layout
Theme color
Choose your colors
Background Color:
Reset

Cable Crimp Terminals Tension Strength Test

There are 2 ways to measure the tension strength of crimped terminals, durability test and break test.

The break test complying with the coresponding part of IEC 60512-16-4: 2008 requires you to determine the maximum force value when the terminal is pulled off. On the other hand, the durability test complying with the coresponding part of JIS C2805: 2010 requires you to pull the crimped terminal continuously at a certain force for 10 seconds, and check the connector part situation after the test.

They are used for R&D and quality control.

Products used:

  • ZTS Serie - Standard Model Digital Force Gauge.
  • MX2 Serie - Standard Type Vertical Motorized Test Stand.
  • FW-12/PW-4 - Rotary Wire Terminal Fixture.
  • GP-15/30 - Knurled Cam Grip.
  • CB-528 - Force Control Cable (MX2/EMX - ZT connection).

·        ZTS series force gauge is recommended in this test.
A dedicated tester ACT-1000N is recommended when testing a large number of crimp terminals to increase efficiency.

This video shows the testing image of objective sample. Some samples may not be suitable to measure with this configuration depending on their materials or shapes.
The example of product configuration is for your reference only. It varies depending on sample, measurement method and testing capacity.
The products used in this video may differ from the example of product configuration.
Please select the right product model for the product configuration. Refer to the specification of each product for the compatibility.